HVAC School - For Techs, By Techs

HVAC Troubleshooting 101 w/ Jim Fultz
In this session from the 2026 HVACR Training Symposium, Jim Fultz walks through his HVAC 101 class to help techs get through any gas furnace call. Jim's core message is to start with your senses, not your meter. Look, listen, smell, and ask the homeowner what they experienced before touching a tool, then use instruments to confirm what your observations suggest.
An 80% furnace has a short list of components and a clear sequence of operations: call for heat, limit and pressure switch checks, inducer start, igniter warm-up, gas valve opening, flame proving, and the timed blower. When a furnace stops partway through that sequence, the stopping point tells you where to look. Jim also encourages techs to cycle a repaired furnace two or three times so they memorize what normal looks like, the way a bank teller learns real currency to spot counterfeits.
From there, Jim goes component by component, mixing practical tests with field stories. Topics include hot surface igniters, PSC and constant torque blower motors, capacitors, flame sensing, gas valves, pressure switches, and thermostat wiring. Along the way, he shares lessons such as checking amp draw even after a capacitor swap, measuring DC as well as AC on modern blower signals, and never assuming a wire's color is consistent from end to end. He also explains why wiring works as pairs, which makes board replacement far easier.
Jim closes with a look at truck stock and time management, pointing out that every parts run costs a billable hour. He also covers some White-Rodgers resources, including the mobile cross-reference app, universal controls, and private-label thermostats.
Topics Covered
Developing a troubleshooting thought process: observe first, measure second
Using the board LED, thermostat batteries, and float switches as quick first checks
Recreating the homeowner's complaint and listening to what customers report
Sequence of operation for an 80% furnace, including typical timings (15-second pre-purge, 17-second warm-up for 120V igniters, 5-second flame proving)
High-voltage versus low-voltage circuits, and why almost every component is wired in pairs
Tracing circuits on wiring diagrams one circuit at a time
Voltage versus continuity versus amperage: when to use each
Tracking down blown low-voltage fuses, from DIY thermostat installs to rubbed wires
Hot surface igniters: silicon carbide versus silicon nitride, cracks, and handling
PSC blowers, capacitor tolerances, and checking amp draw after a replacement
Constant torque (ECM X13) motors and the shift to DC control signals
Flame rectification: how it works, microamp readings, and cleaning the flame rod without sandpaper
Grounding problems, including a furnace that quit after a panel upgrade
Gas valves: DC coils, why you can't ohm them, and checking inlet gas first
Pressure switch testing tips and thermostat wire continuity checks
Truck stock strategy, universal controls, and the cost of parts runs
The key takeaway from this session is to pay attention to where the actual sequence of operations differs from the expected sequence.
This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, Santa Fe Dehumidifiers, and TruTech Tools.
Resources
White-Rodgers by Copeland (website)
Copeland's mobile apps (including Copeland Mobile, White-Rodgers Connect, and Sensi)
HVAC School calculators
Submit a podcast question
Learn about the GRIT Foundation
Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

